smaller reset larger         

Main Menu

All times are in GMT -5 (DST) :: The time is now 5:47 am.

Sub Menu

Category Details
Category Name
Manuals
Category Created
Mon, 2nd Jul 2007
Last Article Update
Fri, 19th Dec 2025
Category Actions
 
(Lost?)

   Manuals

Showing the 113 Articles in this Category 

12024 Polariscope 

 1. Application

2. Data

3. Structure and Principle

4. Operation of the Instrument

5. Maintenance

6. List

7. After-sale Service

View Full Article

13552 Pilot Plant Temperature Controller 

13552 Pilot Plant Temperature Controller Manual

View Full Article

13553 Motor Controller User Manual & Data Acquisition Utility 

 Download attachment for complete information including: User Manual in PDF format & Ace Glass Data Acquisition Utility software

View Full Article

14026 High Vacuum Pump 

Product Specifications and Operation Manual

View Full Article

5277-10 pH Electrode Instructions 

 INTRODUCTION

 

This combination pH electrode comes in many styles and is designed for maximum reliability, accuracy, and ease of use.  The outer body can be glass, epoxy, or other plastic materials.  The plastic body electrode is available with a permanent non-removable bulb guard or a removable guard which is shipped attached to the cable.  The reference half-cell can be refillable or permanently sealed at the factory and non-refillable.  The refillable electrode will have one or two fill holes located underneath the cap at the top of the electrode.  Some models are constructed with a built-in temperature sensor(ATC).   The electrode is shipped with a protective boot filled with a membrane/junction wetting agent (1:1 pH4 buffer/KCl).  Crystals which may form around the protective boot in no way affect electrode performance.

 

PREPARATION

 

1.        Remove the pH bulb protector boot covering the pH bulb and rinse the bulb area with deionized water or pH buffer.  Save the boot if the electrode will be stored.  It is possible that air bubbles may have migrated into the pH sensitive bulb during shipment.  Since the electrode is not able to function with air behind the pH bulb, gently shake the electrode downward in the same manner as a clinical thermometer to remove any trapped air bubbles.

 

2.        Sleeve junction electrode: Remove parafilm from underneath sleeve and slide teflon or glass sleeve firmly into position on tip of electrode.  Measurements should be made with only the lower part of sleeve immersed.  For sleeve junction electrodes, when the liquid junction becomes clogged, the electrode may be flushed after loosening the sleeve.  If the sleeve freezes in place, soak it in warm water to loosen it.  After the sleeve is free, replenish the filling solution.

 

3.        Reference electrodes that are refillable: For electrodes shipped with fill-hole plugs, remove the shipping tape covering the rubber fill-hole plug and withdraw the plug to expose the fill-hole.  For electrodes shipped with a sleeve over the fill-hole(s), slide the rubber sleeve down and remove the shipping tape to expose the fill-hole.  Fill the refillable electrodes with any fill solution(s) shipped with the electrode to a level just below the fill-hole(s).  The fill hole should be open whenever  the electrode is in solution.

 

4.        Attach the removable bulb guard, if provided, to the epoxy electrode by sliding guard over the end of the electrode.

 

5.        Prior to first usage, or after long-term storage, immerse the pH bulb in pH buffer for thirty minutes.  This hydrates the pH bulb and wets the reference junction for optimum performance.  The electrode is now ready for use.

 

REQUIRED MATERIALS

 

Meter: This electrode will work with any pH and/or mV meter commercially available.  Consult the meter instruction manual for specific details on connecting the pH electrode to the meter or operating the meter.  Some electrodes may require adaptor cables or detachable lead cables for connection to the pH and/or mV meter.

 

Buffers:  For precise electrode standardization, two buffers are required, of which one should be close to the desired sample pH.  pH 7.00 (at 25°C) buffer is recommended for initial standardization followed by pH  4.01 ( at 25°C) or pH 10.01 (at 25°C) buffer to span(slope) the electrode.

 

ELECTRODE STANDARDIZATION

 

1.        Place the electrode in fresh pH 7.00  buffer and stir.  Adjust the meter to read the buffer value according to the meter instruction manual.  If impossible, see cleaning procedures.

 

2.        Rinse the electrode in distilled water and place the electrode in either fresh pH 4.01 buffer or fresh pH 10.01 buffer depending on whether the sample is acidic or basic.  Stir and allow meter reading to stabilize for 30 seconds to one minute.  Adjust the meter reading to the buffer value according to the meter instruction manual.  If impossible, see cleaning procedure.

 

3.        Rinse the electrode with distilled water.  Place in sample and stir.  Allow meter reading to stabilize for 30 seconds to one minute.  Record reading.  For best accuracy, the temperature of the buffers and samples should be identical and at room temperature.

 

ELECTRODE STORAGE

 

For best results, always keep the pH bulb wet, preferably in pH 4.01 buffer with 1/100 part of saturated KCl added.  Other pH buffers or tap water are acceptable storage media, but avoid storage in distilled water.  The protective boot filled with buffer will provide an ideal storage chamber for long periods.  NOTE: Electrodes  should not be stored for a period longer than 6 months for best results.  Electrode stock should be rotated accordingly.

 

TROUBLESHOOTING HINTS

 

Symptom                          Possible Causes                Next Step

 

Out of Range Reading             defective meter                         check meter with shorting plug                                                           defective electrode                check electrode operation

electrode wired incorrectly     check wiring connections                                                                air bubble on pH bulb             remove electrode and reattach

 

Noisy or Unstable Display      defective meter                         check meter with shorting plug

solution not grounded             ground meter and electrode

air bubble on pH bulb             remove electrode and reattach

 

Drift (reading                           pH bulb contaminated             see CLEANING hints

slowly changing                       reference clogged                     see CLEANING hints     

in one direction)                     


 

Low Slope                                buffers contaminated               use fresh buffers

pH bulb contaminated             see CLEANING hints

reference clogged                     see CLEANING hints     

defective electrode                   check electrode operation

 

ELECTRODE CLEANING

 

Electrodes which are mechanically intact with no broken parts can often be restored to normal performance by one of the following procedures:

 

General Cleaning:  Soak the electrode in 1:10 dilution of household laundry bleach in a 0.1-0.5% liquid detergent solution in hot water with vigorous stirring for 15 minutes.  Place junction under warm, running tap water for 15 seconds.  Drain/refill the reference chamber.  Soak the electrode in storage solution for at least 10 minutes.

 

Salt Deposits:  Dissolve the deposit by immersing the electrode in 0.1 M HCl for five minutes, followed by immersion in 0.1M NaOH for five minutes, and thorough rinsing with distilled water.

 

Oil/Grease Films:  Wash electrode pH bulb in a little detergent and water.  Rinse electrode tip with distilled water.

 

Clogged Reference Junction:  Heat a diluted KCl solution to 60-80oC. Place the reference portion of the pH electrode into the heated KCl solution for approximately 10 minutes.  Allow the electrode to cool while immersed in some unheated KCl solution.

 

Protein Deposits:  Dissolve the deposit by immersing the electrode in a 1% pepsin solution with a background of 0.1M HC1 for five minutes, followed by thorough rinsing with distilled water.

 

After any of these special cleaning procedures, remember to drain/refill the reference chamber, if refillable.  Soak the electrode in storage solution for at least 10 minutes.

If these steps fail to restore normal electrode response, replace the electrode.

 

SPECIFICATIONS

 

pH Range:                                        pH 0 to 12 or pH 0 to 14

Slope:                                              59 +/- 3 mV/pH unit at 25°C          

Offset (Asymmetry Potential):         0 mV +/- 25 mV

Accuracy:                                        +/- 0.1 pH unit

Response Time:                               < 10 sec (95% response)

Stability:                                          < 3 mV drift/24 hours

Operating Temperature Range:        variable, consult product literature

Operating Pressure Range: variable, consult product literature

Electrode Length:                            variable, consult product literature

Electrode Width:                              variable, consult product literature

Cable Length:                                  variable or detachable, consult literature

View Full Article

7825 - Helpful Hints for UV Lamp Operation 

 Helpful Hints for UV Lamp Operation - 7825

View Full Article

7900-81 Ultra-Violet Photo Oxidation Unit 

7900-81 Ultra-Violet Photo Oxidation Unit

View Full Article

Ace Glass Mechanical Seal Bearing Technical Manual 

1. Introduction

2. Bearing Specifications

3. Material Composition
 
4. Thread and Adapter Compatibility
 
5. Cooling Requirements
 
6. Installation & Setup
View Full Article

Calibration Instructions for 12125 & 12126 

Synchronize Your Controller to Your Standard.

View Full Article

Impresario - 6458-10 

  Impresario - 6458-10 - Product Manual

View Full Article

Polyscience MM Series Chiller User Manual (Ace 12450) 

 Polyscience MM Series Chiller User Manual (Ace 12450)

View Full Article

14033/14034 Ace-Digivac Precision Vacuum Gauges/Controller General Information 

14033/14034 Ace-Digivac Precision Vacuum Gauges/Controller General Information

View Full Article

5879 Kauffman Chromatographic Column Operating Instructions 

5879 Kauffman Chromatographic Column Operating Instructions

View Full Article

The Quartz Mercury Arc 

The Quartz Mercury Arc

View Full Article

13100 Instructions for applying ACE Plastic Coating 

Instructions for applying 13100, ACE Plastic Coating

View Full Article

Ace Temperature Controllers Operation Manual 

Yes! The document attached to this article covers the following ACE Temperature Controllers:

  • 12102-12
  • 12103-05
  • 12105-14
  • 12106-10
  • 12107-20
  • 12107-46
  • 12108-13
  • 12110-06
  • 12111-15
  • 12111-47
  • 12113-17
  • 12113-50
  • 12125-14
  • 12126-24
  • 12127-30
View Full Article

O-Ring Reference Chart 

O-Ring Reference Chart

View Full Article

J-Kem 260 Timer Manual 

J-Kem 260 Timer Manual

View Full Article

J-Kem 270 User Manual 

J-Kem 270 User Manual

View Full Article

J-Kem 410 User Manual 

J-Kem 410 User Manual

View Full Article

J-Kem Apollo User Manual 

J-Kem Apollo User Manual

View Full Article

13649, 13562, 13584 Ace Stirring Motors 

13649, 13562, 13584 Ace Stirring Motors

View Full Article

Thermometer Separations 

Thermometer Separations

View Full Article

How to Grease Joints and Stopcocks 

How to Grease Joints and Stopcocks

View Full Article

8718/8722/8732 Mercury Filling Instructions 

8718/8722/8732 Mercury Filling Instructions

View Full Article

8733-07/8733-17 Mercury Filling Instructions 

8733-07/8733-17 Mercury Filling Instructions

View Full Article

9601, 9602 or 9603 Important -- Read before operating these Instatherm® Oil Baths 

9601, 9602 or 9603  Important — Read before operating these Instatherm® Oil Baths

View Full Article

9601, 9602, 9603 Ace Instatherm® Instruction Sheet (Important to read before using units) 

9601, 9602, 9603 Ace Instatherm® Instruction Sheet (Important to read before using units)

View Full Article

12087-10 Voltage Controller General Description 

12087-10 Voltage Controller General Description

View Full Article

12160-06 Sensing Head with Water filter, 12160-35 Water Filter 

12160-06 Sensing Head with Water filter, 12160-35 Water Filter

View Full Article

Suggestions for cleaning laboratory glassware 

Suggestions for cleaning laboratory glassware

View Full Article

J-Kem Digital Motor Manual 

J-Kem Digital Motor Manual

View Full Article

J-Kem DVR-1000 User Manual 

J-Kem DVR-1000 User Manual

View Full Article

Julabo Presto LH41 Manual 

Julabo Presto LH41 Manual

View Full Article

Julabo FPW91-SL Manual 

Julabo FPW91-SL Manual

View Full Article

Julabo FPW55-SL Manual 

Julabo FPW55-SL Manual

View Full Article

Julabo FPW52-SL Manual 

Julabo FPW52-SL Manual

View Full Article

Julabo FP51-SL Manual 

Julabo FP51-SL Manual

View Full Article

Julabo FP50-HL Manual 

Julabo FP50-HL Manual

View Full Article

Julabo FP50-ME Manual 

Julabo FP50-ME Manual

View Full Article

Julabo F34-EH Manual 

Julabo F34-EH Manual

View Full Article

Julabo F32-ME Manual 

Julabo F32-ME Manual

View Full Article

Julabo F25-ME Manual 

Julabo F25-ME Manual

View Full Article

Julabo Presto LH50 Manual 

Julabo Presto LH50 Manual

View Full Article

Julabo Presto LH85 Manual 

Julabo Presto LH85 Manual

View Full Article

Julabo Magnum91 Manual 

Julabo Magnum91 Manual

View Full Article

J-Kem DVR 200 User Manual 

J-Kem DVR 200 User Manual

View Full Article

J-Kem Gemini User Manual 

J-Kem Gemini User Manual

View Full Article

J-Kem Quad User Manual 

J-Kem Quad User Manual

View Full Article

8124 Flex Grip Chuck Instructions 

8124 Flex Grip Chuck Instructions

View Full Article

7481 Rotameter Usage Table 

7481 Rotameter Usage Table

View Full Article

J-Kem HCC Series Manual 

J-Kem HCC Series Manual

View Full Article

J-Kem Syringe Pump Manual (Single Pump Unit) 

J-Kem Syringe Pump Manual (Single Pump Unit)

View Full Article

J-Kem Syringe Pump Manual (Dual Pump Unit) 

J-Kem Syringe Pump Manual (Dual Pump Unit)

View Full Article

J-Kem KEM-Comm Software Manual 

J-Kem KEM-Comm Software Manual

View Full Article

J-Kem KEM-Net Software Manual 

J-Kem KEM-Net Software Manual

View Full Article

Julabo FL300 Manual 

Julabo FL300 Manual

View Full Article

5795 Slurry Packing Procedures For Michel-Miller HP/LPLC Glass Columns 

5795 Slurry Packing Procedures For Michel-Miller HP/LPLC Glass Columns

View Full Article

5555 Series 

 

5555 Series, Glass, heavy wall storage bottles-safety coated

View Full Article

6671-14 Repeat Cycle Timer/Control 

6671-14  Repeat Cycle Timer/Control

View Full Article

6711 Circulating Evaporator 

6711 Circulating Evaporator

View Full Article

7233, 7234, 7239, 9485 Solids Dispensing Funnels Instructions 

7233, 7234, 7239, 9485 Solids Dispensing Funnels Instructions

View Full Article

7441-7445 Instruction Sheet 

7441-7445 Instruction Sheet

View Full Article

7470 Ketene-Butadiene Generator Operating Instructions 

7470 Ketene-Butadiene Generator Operating Instructions

View Full Article

7825, 7830 General Operating Instructions 

7825, 7830 General Operating Instructions

View Full Article

7836-20 Assembly/Operating Instructions 

7836-20 Assembly/Operating Instructions

View Full Article

7832 Solid State Relay for Pilot Plants, for Automatic Temperature Control 

7832 Solid State Relay for Pilot Plants, for Automatic Temperature Control

View Full Article

Assembly Instructions for 7840 Reaction Assembly 

Assembly Instructions for 7840 Reaction Assembly

View Full Article

Assembly Instructions for 7858 Low Temperature Immersion Well 

Assembly Instructions for 7858 Low Temperature Immersion Well

View Full Article

6472-210 

Sprayer, clean in Place

View Full Article

6670 Repeat Cycle Timer Operating Instructions 

6670 Repeat Cycle Timer Operating Instructions

View Full Article

6588/6590/6592 

OPERATION OF
6588, 6590 & 6592 COILS

View Full Article

6469 Series 

6469 Series - Ace 12L and 22L pilot plants

View Full Article

6472 Series 

6472 Series - Pilot Plant Reactors

View Full Article

6555 Series 

Steam Distillation Apparatus

View Full Article

Where can I find more technical information? 

In additional to the information found in this Technical Support section of our website, see also the Technical Section of our General Catalog. Other tech items are also interspersed throughout the catalog. Of course, you can always call us at 800-223-4524 and speak directly to one of our engineers.

View Full Article

7818 Ace-Burlitch Inert Atmosphere System Assembly & Instructions 

Ace-Burlitch Inert Atmosphere System Assembly & Instructions

View Full Article

J-Kem 150/150 Timer Product Manual 

J-Kem 150/150 Timer Product Manual

View Full Article

J-Kem 250 User Manual 

J-Kem 250 User Manual

View Full Article

J-Kem 210/210 Timer Manual 

J-Kem 210/210 Timer Manual

View Full Article

Love Controls 16A Manual 

Love Controls 16A Manual

12107
12111
12113

View Full Article

Love Controls 32A Manual 

Love Controls 32A Manual

12116
12125
12126
12127

View Full Article

7861 Reaction Assembly Instructions 

7861 Reaction Assembly Instructions

View Full Article

7883-02 UV Lamp Reflector Assembly Instructions 

7883-02 UV Lamp Reflector Assembly Instructions

View Full Article

8769 Pressure Relief Valve Instruction sheet 

8769 Pressure Relief Valve Instruction sheet

View Full Article

9319 Short Path Still Instruction Sheet 

9319 Short Path Still Instruction Sheet

View Full Article

9331-9333 Concentric Tube Fractionating Unit Assembly & Operating Instructions 

9331-9333 Concentric Tube Fractionating Unit Assembly & Operating Instructions

View Full Article

9595 Microscale Spinning Band Column 

9595 Microscale Spinning Band Column

View Full Article

9599 Spinning Hickman-Hinkle Distillation Column 

9599 Spinning Hickman-Hinkle Distillation Column

View Full Article

12081-05 PowerStat® with Ace Warning Glow Operating Instruction Sheet 

12081-05 PowerStat® with Ace Warning Glow Operating Instruction Sheet

View Full Article

Complete Photochem Packet 

Complete Photochem Packet

View Full Article

12160-10 Water-Flo Power Cut-Off & 12162-07 Water Flow Power Cut-Off with Timer 

12160-10 Water-Flo Power Cut-Off & 12162-07 Water Flow Power Cut-Off with Timer

View Full Article

12164-20 Water-Flo Power Cut-Off 

12164-20 Water-Flo Power Cut-Off

View Full Article

13530-10, 3532-10 Solid State Power Controllers Operating Instructions 

13530-10, 3532-10 Solid State Power Controllers Operating Instructions

View Full Article

O-Ring Chemical Compatibility Chart 

O-Ring Chemical Compatibility Chart

View Full Article

8766 Valve, Rapid Purge, Firestone* 

8766 Valve, Rapid Purge, Firestone*

View Full Article

8741 Vacuum Regulator Operating Instructions 

8741 Vacuum Regulator Operating Instructions

View Full Article

7892 Platform Reactor Operating Instructions 

7892 Platform Reactor Operating Instructions

View Full Article

7901 Flow-Thru Photo-Oxidation Unit Operating Instructions 

7901 Flow-Thru Photo-Oxidation Unit Operating Instructions

View Full Article

7985 Ostwald Viscometer Instructions 

7985 Ostwald Viscometer Instructions

View Full Article

7988 Cannon-Fenske Viscometer Instructions 

7988 Cannon-Fenske Viscometer Instructions

View Full Article

8081 Flexible Shaft Operation and Service Instructions 

8081 Flexible Stirring Shaft Operation and Service Instructions

View Full Article

8111/8112 Stuffing/Packing Box w/Wire Retainers Instruction Sheet 

8111/8112 Stuffing/Packing Box w/Wire Retainers Instruction Sheet

View Full Article

8318 Thermometer General Instructions 

8318 Thermometer General Instructions

View Full Article

8702 Three-Stage Oil Vapor Pump Operating Instructions 

8702 Three-Stage Oil Vapor Pump Operating Instructions

View Full Article

8715 McLeod Gauge Operating Instructions 

8715 McLeod Gauge Operating Instructions

View Full Article

8726 and 8728 Instructions 

8726 & 8728 Instructions

View Full Article