Manuals
Showing the 113 Articles in this Category
- 12024 Polariscope
- 12116 Temperature Controller - Manuals and Software
- 13552 Pilot Plant Temperature Controller
- 13553 Motor Controller User Manual & Data Acquisition Utility
- 14026 High Vacuum Pump
- 5277-10 pH Electrode Instructions
- 7825 - Helpful Hints for UV Lamp Operation
- 7900-81 Ultra-Violet Photo Oxidation Unit
- Ace Glass Mechanical Seal Bearing Technical Manual
- Calibration Instructions for 12125 & 12126
- Impresario - 6458-10
- Polyscience MM Series Chiller User Manual (Ace 12450)
- 7891-40 UV Aborption Data
- 14033/14034 Ace-Digivac Precision Vacuum Gauges/Controller General Information
- 5879 Kauffman Chromatographic Column Operating Instructions
- The Quartz Mercury Arc
- 13100 Instructions for applying ACE Plastic Coating
- Ace Temperature Controllers Operation Manual
- O-Ring Reference Chart
- J-Kem 260 Timer Manual
- J-Kem 270 User Manual
- J-Kem 410 User Manual
- J-Kem Apollo User Manual
- 13649, 13562, 13584 Ace Stirring Motors
- Thermometer Separations
- How to Grease Joints and Stopcocks
- 8718/8722/8732 Mercury Filling Instructions
- 8733-07/8733-17 Mercury Filling Instructions
- 9601, 9602 or 9603 Important -- Read before operating these Instatherm® Oil Baths
- 9601, 9602, 9603 Ace Instatherm® Instruction Sheet (Important to read before using units)
- 12087-10 Voltage Controller General Description
- 12160-06 Sensing Head with Water filter, 12160-35 Water Filter
- Suggestions for cleaning laboratory glassware
- J-Kem Digital Motor Manual
- J-Kem DVR-1000 User Manual
- Julabo Presto LH41 Manual
- Julabo FPW91-SL Manual
- Julabo FPW55-SL Manual
- Julabo FPW52-SL Manual
- Julabo FP51-SL Manual
- Julabo FP50-HL Manual
- Julabo FP50-ME Manual
- Julabo F34-EH Manual
- Julabo F32-ME Manual
- Julabo F25-ME Manual
- Julabo Presto LH50 Manual
- Julabo Presto LH85 Manual
- Julabo Magnum91 Manual
- J-Kem DVR 200 User Manual
- J-Kem Gemini User Manual
- J-Kem Quad User Manual
- 8124 Flex Grip Chuck Instructions
- 7481 Rotameter Usage Table
- J-Kem HCC Series Manual
- J-Kem Syringe Pump Manual (Single Pump Unit)
- J-Kem Syringe Pump Manual (Dual Pump Unit)
- J-Kem KEM-Comm Software Manual
- J-Kem KEM-Net Software Manual
- Julabo FL300 Manual
- 5795 Slurry Packing Procedures For Michel-Miller HP/LPLC Glass Columns
- 5555 Series
- 6671-14 Repeat Cycle Timer/Control
- 6711 Circulating Evaporator
- 7233, 7234, 7239, 9485 Solids Dispensing Funnels Instructions
- 7441-7445 Instruction Sheet
- 7470 Ketene-Butadiene Generator Operating Instructions
- 7825, 7830 General Operating Instructions
- 7836-20 Assembly/Operating Instructions
- 7832 Solid State Relay for Pilot Plants, for Automatic Temperature Control
- Assembly Instructions for 7840 Reaction Assembly
- Assembly Instructions for 7858 Low Temperature Immersion Well
- 6472-210
- 6670 Repeat Cycle Timer Operating Instructions
- 6588/6590/6592
- 6469 Series
- 6472 Series
- 6555 Series
- Where can I find more technical information?
- 7818 Ace-Burlitch Inert Atmosphere System Assembly & Instructions
- J-Kem 150/150 Timer Product Manual
- J-Kem 250 User Manual
- J-Kem 210/210 Timer Manual
- Love Controls 16A Manual
- Love Controls 32A Manual
- 7861 Reaction Assembly Instructions
- 7883-02 UV Lamp Reflector Assembly Instructions
- 8769 Pressure Relief Valve Instruction sheet
- 9319 Short Path Still Instruction Sheet
- 9331-9333 Concentric Tube Fractionating Unit Assembly & Operating Instructions
- 9595 Microscale Spinning Band Column
- 9599 Spinning Hickman-Hinkle Distillation Column
- 12081-05 PowerStat® with Ace Warning Glow Operating Instruction Sheet
- Complete Photochem Packet
- 12160-10 Water-Flo Power Cut-Off & 12162-07 Water Flow Power Cut-Off with Timer
- 12164-20 Water-Flo Power Cut-Off
- 13530-10, 3532-10 Solid State Power Controllers Operating Instructions
- O-Ring Chemical Compatibility Chart
- 8766 Valve, Rapid Purge, Firestone*
- 8741 Vacuum Regulator Operating Instructions
- 7892 Platform Reactor Operating Instructions
- 7901 Flow-Thru Photo-Oxidation Unit Operating Instructions
- 7985 Ostwald Viscometer Instructions
- 7988 Cannon-Fenske Viscometer Instructions
- 8055 Assembly
- 8081 Flexible Shaft Operation and Service Instructions
- 8111/8112 Stuffing/Packing Box w/Wire Retainers Instruction Sheet
- 8318 Thermometer General Instructions
- 8702 Three-Stage Oil Vapor Pump Operating Instructions
- 8715 McLeod Gauge Operating Instructions
- 8726 and 8728 Instructions
- 7891-42 UV Aborption Data
- 7891-46 UV Aborption Data
- 7891-44 UV Aborption Data
12024 Polariscope
1. Application
2. Data
3. Structure and Principle
4. Operation of the Instrument
5. Maintenance
6. List
7. After-sale Service
| View Full Article |
12116 Temperature Controller - Manuals and Software
12116-15 Quick Start and Setup Software
| View Full Article |
13552 Pilot Plant Temperature Controller
13552 Pilot Plant Temperature Controller Manual
| View Full Article |
13553 Motor Controller User Manual & Data Acquisition Utility
Download attachment for complete information including: User Manual in PDF format & Ace Glass Data Acquisition Utility software
| View Full Article |
5277-10 pH Electrode Instructions
INTRODUCTION
This combination pH electrode comes in many styles and is designed for maximum reliability, accuracy, and ease of use. The outer body can be glass, epoxy, or other plastic materials. The plastic body electrode is available with a permanent non-removable bulb guard or a removable guard which is shipped attached to the cable. The reference half-cell can be refillable or permanently sealed at the factory and non-refillable. The refillable electrode will have one or two fill holes located underneath the cap at the top of the electrode. Some models are constructed with a built-in temperature sensor(ATC). The electrode is shipped with a protective boot filled with a membrane/junction wetting agent (1:1 pH4 buffer/KCl). Crystals which may form around the protective boot in no way affect electrode performance.
PREPARATION
1. Remove the pH bulb protector boot covering the pH bulb and rinse the bulb area with deionized water or pH buffer. Save the boot if the electrode will be stored. It is possible that air bubbles may have migrated into the pH sensitive bulb during shipment. Since the electrode is not able to function with air behind the pH bulb, gently shake the electrode downward in the same manner as a clinical thermometer to remove any trapped air bubbles.
2. Sleeve junction electrode: Remove parafilm from underneath sleeve and slide teflon or glass sleeve firmly into position on tip of electrode. Measurements should be made with only the lower part of sleeve immersed. For sleeve junction electrodes, when the liquid junction becomes clogged, the electrode may be flushed after loosening the sleeve. If the sleeve freezes in place, soak it in warm water to loosen it. After the sleeve is free, replenish the filling solution.
3. Reference electrodes that are refillable: For electrodes shipped with fill-hole plugs, remove the shipping tape covering the rubber fill-hole plug and withdraw the plug to expose the fill-hole. For electrodes shipped with a sleeve over the fill-hole(s), slide the rubber sleeve down and remove the shipping tape to expose the fill-hole. Fill the refillable electrodes with any fill solution(s) shipped with the electrode to a level just below the fill-hole(s). The fill hole should be open whenever the electrode is in solution.
4. Attach the removable bulb guard, if provided, to the epoxy electrode by sliding guard over the end of the electrode.
5. Prior to first usage, or after long-term storage, immerse the pH bulb in pH buffer for thirty minutes. This hydrates the pH bulb and wets the reference junction for optimum performance. The electrode is now ready for use.
REQUIRED MATERIALS
Meter: This electrode will work with any pH and/or mV meter commercially available. Consult the meter instruction manual for specific details on connecting the pH electrode to the meter or operating the meter. Some electrodes may require adaptor cables or detachable lead cables for connection to the pH and/or mV meter.
Buffers: For precise electrode standardization, two buffers are required, of which one should be close to the desired sample pH. pH 7.00 (at 25°C) buffer is recommended for initial standardization followed by pH 4.01 ( at 25°C) or pH 10.01 (at 25°C) buffer to span(slope) the electrode.
ELECTRODE STANDARDIZATION
1. Place the electrode in fresh pH 7.00 buffer and stir. Adjust the meter to read the buffer value according to the meter instruction manual. If impossible, see cleaning procedures.
2. Rinse the electrode in distilled water and place the electrode in either fresh pH 4.01 buffer or fresh pH 10.01 buffer depending on whether the sample is acidic or basic. Stir and allow meter reading to stabilize for 30 seconds to one minute. Adjust the meter reading to the buffer value according to the meter instruction manual. If impossible, see cleaning procedure.
3. Rinse the electrode with distilled water. Place in sample and stir. Allow meter reading to stabilize for 30 seconds to one minute. Record reading. For best accuracy, the temperature of the buffers and samples should be identical and at room temperature.
ELECTRODE STORAGE
For best results, always keep the pH bulb wet, preferably in pH 4.01 buffer with 1/100 part of saturated KCl added. Other pH buffers or tap water are acceptable storage media, but avoid storage in distilled water. The protective boot filled with buffer will provide an ideal storage chamber for long periods. NOTE: Electrodes should not be stored for a period longer than 6 months for best results. Electrode stock should be rotated accordingly.
TROUBLESHOOTING HINTS
Symptom Possible Causes Next Step
Out of Range Reading defective meter check meter with shorting plug defective electrode check electrode operation
electrode wired incorrectly check wiring connections air bubble on pH bulb remove electrode and reattach
Noisy or Unstable Display defective meter check meter with shorting plug
solution not grounded ground meter and electrode
air bubble on pH bulb remove electrode and reattach
Drift (reading pH bulb contaminated see CLEANING hints
slowly changing reference clogged see CLEANING hints
in one direction)
Low Slope buffers contaminated use fresh buffers
pH bulb contaminated see CLEANING hints
reference clogged see CLEANING hints
defective electrode check electrode operation
ELECTRODE CLEANING
Electrodes which are mechanically intact with no broken parts can often be restored to normal performance by one of the following procedures:
General Cleaning: Soak the electrode in 1:10 dilution of household laundry bleach in a 0.1-0.5% liquid detergent solution in hot water with vigorous stirring for 15 minutes. Place junction under warm, running tap water for 15 seconds. Drain/refill the reference chamber. Soak the electrode in storage solution for at least 10 minutes.
Salt Deposits: Dissolve the deposit by immersing the electrode in 0.1 M HCl for five minutes, followed by immersion in 0.1M NaOH for five minutes, and thorough rinsing with distilled water.
Oil/Grease Films: Wash electrode pH bulb in a little detergent and water. Rinse electrode tip with distilled water.
Clogged Reference Junction: Heat a diluted KCl solution to 60-80oC. Place the reference portion of the pH electrode into the heated KCl solution for approximately 10 minutes. Allow the electrode to cool while immersed in some unheated KCl solution.
Protein Deposits: Dissolve the deposit by immersing the electrode in a 1% pepsin solution with a background of 0.1M HC1 for five minutes, followed by thorough rinsing with distilled water.
After any of these special cleaning procedures, remember to drain/refill the reference chamber, if refillable. Soak the electrode in storage solution for at least 10 minutes.
If these steps fail to restore normal electrode response, replace the electrode.
SPECIFICATIONS
pH Range: pH 0 to 12 or pH 0 to 14
Slope: 59 +/- 3 mV/pH unit at 25°C
Offset (Asymmetry Potential): 0 mV +/- 25 mV
Accuracy: +/- 0.1 pH unit
Response Time: < 10 sec (95% response)
Stability: < 3 mV drift/24 hours
Operating Temperature Range: variable, consult product literature
Operating Pressure Range: variable, consult product literature
Electrode Length: variable, consult product literature
Electrode Width: variable, consult product literature
Cable Length: variable or detachable, consult literature
| View Full Article |
7825 - Helpful Hints for UV Lamp Operation
Helpful Hints for UV Lamp Operation - 7825
| View Full Article |
7900-81 Ultra-Violet Photo Oxidation Unit
7900-81 Ultra-Violet Photo Oxidation Unit
| View Full Article |
Ace Glass Mechanical Seal Bearing Technical Manual
1. Introduction
2. Bearing Specifications
| View Full Article |
Calibration Instructions for 12125 & 12126
Synchronize Your Controller to Your Standard.
| View Full Article |
Polyscience MM Series Chiller User Manual (Ace 12450)
Polyscience MM Series Chiller User Manual (Ace 12450)
| View Full Article |
7891-40 UV Aborption Data
Yes. 7891-40 UV absorption data can be found here:
http://www.grayglass.net/glass.cfm/catid/0/conid/199
| View Full Article |
14033/14034 Ace-Digivac Precision Vacuum Gauges/Controller General Information
14033/14034 Ace-Digivac Precision Vacuum Gauges/Controller General Information
| View Full Article |
5879 Kauffman Chromatographic Column Operating Instructions
5879 Kauffman Chromatographic Column Operating Instructions
| View Full Article |
13100 Instructions for applying ACE Plastic Coating
Instructions for applying 13100, ACE Plastic Coating
| View Full Article |
Ace Temperature Controllers Operation Manual
Yes! The document attached to this article covers the following ACE Temperature Controllers:
- 12102-12
- 12103-05
- 12105-14
- 12106-10
- 12107-20
- 12107-46
- 12108-13
- 12110-06
- 12111-15
- 12111-47
- 12113-17
- 12113-50
- 12125-14
- 12126-24
- 12127-30
| View Full Article |
8718/8722/8732 Mercury Filling Instructions
8718/8722/8732 Mercury Filling Instructions
| View Full Article |
8733-07/8733-17 Mercury Filling Instructions
8733-07/8733-17 Mercury Filling Instructions
| View Full Article |
9601, 9602 or 9603 Important -- Read before operating these Instatherm® Oil Baths
9601, 9602 or 9603 Important — Read before operating these Instatherm® Oil Baths
| View Full Article |
9601, 9602, 9603 Ace Instatherm® Instruction Sheet (Important to read before using units)
9601, 9602, 9603 Ace Instatherm® Instruction Sheet (Important to read before using units)
| View Full Article |
12087-10 Voltage Controller General Description
12087-10 Voltage Controller General Description
| View Full Article |
12160-06 Sensing Head with Water filter, 12160-35 Water Filter
12160-06 Sensing Head with Water filter, 12160-35 Water Filter
| View Full Article |
Suggestions for cleaning laboratory glassware
Suggestions for cleaning laboratory glassware
| View Full Article |
J-Kem Syringe Pump Manual (Single Pump Unit)
J-Kem Syringe Pump Manual (Single Pump Unit)
| View Full Article |
J-Kem Syringe Pump Manual (Dual Pump Unit)
J-Kem Syringe Pump Manual (Dual Pump Unit)
| View Full Article |
5795 Slurry Packing Procedures For Michel-Miller HP/LPLC Glass Columns
5795 Slurry Packing Procedures For Michel-Miller HP/LPLC Glass Columns
| View Full Article |
7233, 7234, 7239, 9485 Solids Dispensing Funnels Instructions
7233, 7234, 7239, 9485 Solids Dispensing Funnels Instructions
| View Full Article |
7470 Ketene-Butadiene Generator Operating Instructions
7470 Ketene-Butadiene Generator Operating Instructions
| View Full Article |
7825, 7830 General Operating Instructions
7825, 7830 General Operating Instructions
| View Full Article |
7832 Solid State Relay for Pilot Plants, for Automatic Temperature Control
7832 Solid State Relay for Pilot Plants, for Automatic Temperature Control
| View Full Article |
Assembly Instructions for 7840 Reaction Assembly
Assembly Instructions for 7840 Reaction Assembly
| View Full Article |
Assembly Instructions for 7858 Low Temperature Immersion Well
Assembly Instructions for 7858 Low Temperature Immersion Well
| View Full Article |
6670 Repeat Cycle Timer Operating Instructions
6670 Repeat Cycle Timer Operating Instructions
| View Full Article |
Where can I find more technical information?
In additional to the information found in this Technical Support section of our website, see also the Technical Section of our General Catalog. Other tech items are also interspersed throughout the catalog. Of course, you can always call us at 800-223-4524 and speak directly to one of our engineers.
| View Full Article |
7818 Ace-Burlitch Inert Atmosphere System Assembly & Instructions
Ace-Burlitch Inert Atmosphere System Assembly & Instructions
| View Full Article |
7883-02 UV Lamp Reflector Assembly Instructions
7883-02 UV Lamp Reflector Assembly Instructions
| View Full Article |
8769 Pressure Relief Valve Instruction sheet
8769 Pressure Relief Valve Instruction sheet
| View Full Article |
9331-9333 Concentric Tube Fractionating Unit Assembly & Operating Instructions
9331-9333 Concentric Tube Fractionating Unit Assembly & Operating Instructions
| View Full Article |
9599 Spinning Hickman-Hinkle Distillation Column
9599 Spinning Hickman-Hinkle Distillation Column
| View Full Article |
12081-05 PowerStat® with Ace Warning Glow Operating Instruction Sheet
12081-05 PowerStat® with Ace Warning Glow Operating Instruction Sheet
| View Full Article |
12160-10 Water-Flo Power Cut-Off & 12162-07 Water Flow Power Cut-Off with Timer
12160-10 Water-Flo Power Cut-Off & 12162-07 Water Flow Power Cut-Off with Timer
| View Full Article |
13530-10, 3532-10 Solid State Power Controllers Operating Instructions
13530-10, 3532-10 Solid State Power Controllers Operating Instructions
| View Full Article |
8741 Vacuum Regulator Operating Instructions
8741 Vacuum Regulator Operating Instructions
| View Full Article |
7892 Platform Reactor Operating Instructions
7892 Platform Reactor Operating Instructions
| View Full Article |
7901 Flow-Thru Photo-Oxidation Unit Operating Instructions
7901 Flow-Thru Photo-Oxidation Unit Operating Instructions
| View Full Article |
7988 Cannon-Fenske Viscometer Instructions
7988 Cannon-Fenske Viscometer Instructions
| View Full Article |
8081 Flexible Shaft Operation and Service Instructions
8081 Flexible Stirring Shaft Operation and Service Instructions
| View Full Article |
8111/8112 Stuffing/Packing Box w/Wire Retainers Instruction Sheet
8111/8112 Stuffing/Packing Box w/Wire Retainers Instruction Sheet
| View Full Article |
8702 Three-Stage Oil Vapor Pump Operating Instructions
8702 Three-Stage Oil Vapor Pump Operating Instructions
| View Full Article |